درباره مجله عضویت در مجله شناسنامه مجله ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() مقالات منتشر شده ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() آمار بازدید ![]() ![]() ![]() ![]() ![]() |
صفحه اصلی > Comparison of Standard No. 2800 with ASCE7 to Scale Earthquake Records for Seismic Assessment of Existing Steel Oil Storage Tanks
.: Comparison of Standard No. 2800 with ASCE7 to Scale Earthquake Records for Seismic Assessment of Existing Steel Oil Storage Tanks Comparison of Standard No. 2800 with ASCE7 to Scale Earthquake Records for Seismic Assessment of Existing Steel Oil Storage Tanks
Hassan Dezgani1, Hossein Tahghighi 2* 1-Civil Engineering Department, Faculty of Engineering, University of Kashan, Kashan, Iran 2- Civil Engineering Department, Faculty of Engineering, University of Kashan, Kashan, Iran
* tahghighi@kashanu.ac.ir
Received: January 2019 Accepted: February 2019
Abstract
The significance of earthquake effects on storage tanks compels researchers to investigate tanks seismic responses. In spite of the recent design codes developments, there is no accepted procedure to scale ground motions to perform time-history analysis for these very stiff structures. Nevertheless, standards for conventional structures have long been minimized in a predefined range of periods the difference between the response spectra of chosen records and the target spectrum. Since design specifications have important differences in their scaling procedures, it gives rise to affect on seismic response of structures. In this paper, the various seismic responses of several existing cylindrical tanks in an oil storage complex in Kashan, Iran are evaluated. The earthquake records have been separately scaled according to the procedure described in Iranian Standard No. 2800 and ASCE/SEI 7-10. The results indicate the different consequences of the scaling procedures for the tanks responses.
Keywords: Storage tank, Design code, Scaling procedure, Target spectrum, Seismic response. |
Journal of Science and Engineering Elites www.ElitesJournal.ir www.ElitesJournal.com پست الکترونیک ( ایمیل) : Info@elitesjournal.com تلفن دبیرخانه: 44258197 -021 ساعات پاسخگوئی به تماس: همه روزه از ساعت 11 الی 17 (به جز جمعه ها و ایام تعطیل) فکس دبیرخانه : 89780710-021 |